Intelligent Track Plate Fluorescent Magnetic Particle Flaw Detection System
◆ Equipment Specifications
1. Circumferential Magnetizing Force: AC 0–10,000 AT (continuously adjustable), with automatic tracking and power-off phase control;
2. Longitudinal Magnetizing Force: AC 0–10,000 AT (continuously adjustable), with automatic tracking and power-off phase control;
3. Equipment Duty Cycle: ≥ 50%;
4. Magnetization Performance: Clear indications displayed on a Type A1 15/50 test piece;
5. Operating Mode: Manual Control / Automatic Control;
6. Rotation Method: Motorized rotation;
7. Clamping Method: Pneumatic clamping;
8. Demagnetization Method: Attenuating in-situ demagnetization;
9. Electrode Spacing: 0–800 mm (continuously adjustable; manual adjustment);
10. Demagnetizing Force: AC 10,000 AT – 0;
11. Demagnetization Residual Field: ≤ 2 GS;
12. Inspection Cycle Time: 18 seconds per workpiece (calculated based on the maximum workpiece size; excluding manual observation time);
13. Overall Dimensions: Main Inspection Unit: Approx. 21,000 (L) × 3,800 (W) × 3,500 (H) mm;
14. Power Supply: 3-phase, 4-wire; 380 V ± 10%; 50 Hz;
15. Loading/Unloading Method: Robotic arm with vision-guided positioning;